4. Detach
TlOO
(main
P.C.
board)
Unsoldcring.
CD
3 Lead wires, black, blue
and
brown.- KlOI (Resistor)
® 2 land areas 0-1201 (Light sensor)
@ 1 land area
.1230
(X contact)
@ 9 land areas O-T301 (Viewfinder contact board)
@ 5 land areas T331 (Shutter magnet relay
P.C.
board)
@ Remove from guide sections
of
D37 (FPC install plate) and D59 (magnet plate).
(/) T3
(FPC
retainer screw), CNL-D 1.7 x2.5 x3, Peel
off
double-sided taped section
and
remove
TlOO.