TRIO Panel Formwork
Instructions for Assembly and Use – Standard Configuration
A10 Offsets
Wall offsets
Wall offset ≤ 20 cm
Pos. Components
23 Compensation Waler TAR 85
29 Hook Tie DW 15/400
50 Compensation provided by contractor
51 Filler plate
21 Panel TR 30
20 Alignment Coupler BFD
(additional BFD from 12 cm)
(Fig. A10.01)
Wall offset 21 – 80 cm
Consisting of inside and outside corners.
Pos. Components
5 TRIO Inside Corner TE
14 Panel TR 60
22 Multi Panel TRM 72
23 Compensation Waler TAR 85
25 Stopend Tie TS
50 Compensation provided by contractor
(Fig. A10.02)
Wall offset 81 – 90 cm
Consisting of inside and outside corners.
Pos. Components
5 TRIO Inside Corner TE
14 Panel TR 60
22 Multi Panel TRM 72
23 Compensation Waler TAR 85
25 Stopend Tie TS
38 Additional tie points
50 Compensation provided by contractor
(Fig. A10.03)
Wall offset 91 – 100 cm
Consisting of inside and outside corners.
Pos. Components
5 TRIO Inside Corner TE
14 Panel TR 60
20 Alignment Coupler BFD
22 Multi Panel TRM 72
50 Compensation provided by contractor
(Fig. A10.04)
≤ 20
Fig. A10.02
Fig. A10.03
Fig. A10.04
Fig. A10.01
TRM 72
21 – 80
TRM 72
TRM 72
81 – 90
TRM 72
TRM 72
91 – 100
TRM 72
Locating board facilitates the positioning
of the formwork panel.
Shown:
Wall thickness 30 cm