4
Intended use
Introduction
Application
The standard configuration includes
formwork for vertical walls up to 8.10 m
high and wall thicknesses from 18 to
40 cm including Push-Pull Props and
safety equipment.
As anchor systems, DW 15 or DW 20
are used.
System dimensions
Panels are available in the following
heights:
3.30 m (steel)
2.70 m (steel and aluminium)
1.20 m (steel)
0.90 m (aluminium)
0.60 m (steel)
The panel size increments are 30 cm.
Product description
PERI products have been designed
for exclusive use in the industrial
and commercial sectors by qualified
personnel only.
PERI TRIO is a panel formwork used
for forming walls and columns with
different dimensions.
The panels can be used both vertically
and horizontally.
TRIO only requires a few panel widths.
Only one part is required for all panel
connections, the Alignment Coupler
BFD. This allows compensations up
to 10 cm and height extensions up to
5.40 m without any additional bracing.
System components such as the Shaft
Panel or the Stopend Panel for continu-
ous reinforcement and the installation of
water bars make forming operations
very easy.
Accessories such as concreting
plattforms and a complete platform
system provide safe working conditions.
Components made of steel are coloured
red – aluminium components are yellow
powder-coated.
Instructions on use
The use in a way not intended, deviating
from the standard configuration or the
intended use according to the Instruc-
tions for Assembly and Use, represents
a misapplication with a potential safety
risk, e.g. risk of falling.
Only PERI original parts may be used.
The use of other products and spare
parts is not allowed.
Changes to PERI components are not
permitted.
Technical data
Fresh concrete pressure
according to DIN 18218
Evenness according to
DIN 18202
TRIO 270 Steel
Hydrostatic pressure 67.5 kN/m² line 7
Constant pressure 56.0 kN/m² line 7
Constant pressure 81.0 kN/m² line 6
TRIO 270 Alu
Hydrostatic pressure 67.5 kN/m² line 7
TRIO 330
Hydrostatic pressure 82.5 kN/m² line 7
Constant pressure 75.0 kN/m² line 7
Constant pressure 83.0 kN/m² line 6
TRIO Panel Formwork
Instructions for Assembly and Use – Standard Configuration
AuV TRIO EX.indb 4 11.10.17 09:44