PG DRIVES TECHNOLOGY
27
CHAPTER 2 - INSTALLATION
SK77898/2
3.2.2 Position
The Power Module must be mounted in a position where it is not exposed to conditions
of water or dust above those specified in ISO7176/9.
The Power Module is designed to withstand levels of shock and vibration experienced
when mounted to the chassis of a wheelchair. The Power Module has been tested in
accordance with IEC60068-2-29 and 34 for Bump and Random Vibration
respectively. Direct impacts onto the unit should be avoided.
The Power Module has excellent thermal performance but, to improve this further, it
may be secured against a metal part of the wheelchair chassis. To provide even
better thermal performance, a non-silicone thermally conductive paste or pad may
be applied between the Power Module and the wheelchair chassis.
Mount the control system in a position allowing a free flow of air around the case.
Contact PGDT if you need further advice.
3.2.3 Cables
The cables to the Power Module must be routed and secured in such a way as to
prevent damage to them, for example by cutting or crushing.
POWER MODULE MOUNTING HOLE POSITIONS
161.0mm / 6.34"