EasyManuals Logo

Philips Respironics SimplyGo Mini User Manual

Philips Respironics SimplyGo Mini
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
7
SimplyGo Mini User Manual
English
Warnings (continued)
Do not modify this system or equipment in any way� Modications
could result in hazards to the user
The device does not require routine servicing or preventative
maintenance other than inspection for normal wear or damage and
device cleaning as indicated in sections “Caring for your Battery” and
“Caring for your SimplyGo Mini System�
The use of this equipment adjacent to or stacked with other
equipment should be avoided because it could result in improper
operation�
Medical Electrical Equipment needs special precautions regarding
EMC and needs to be installed and put into service according to the
EMC information provided in this manual�
The SimplyGo Mini is designed to meet current electromagnetic
compatibility requirements� However, if you suspect operation
of this devices essential performance or its signicant functions
are interfered by or interferes with the normal operation of other
electronic devices (such as TV, radio or other household appliances),
try relocating the appliance or the device until the interference stops,
or plugging the device into a dierent power outlet controlled by
a separate circuit breaker or fuse� If performance continues to be
aected, discontinue use and contact your home care provider
Portable RF communications equipment (including peripherals such
as antenna cables and external antennas) should be used no closer
than 30 cm (12 inches) to any part of the device, including cables
specied by the manufacturer� See the EMC section of this manual for
distances to observe between RF communications equipment and
the device to avoid interference�
Do not use this device near active high frequency surgical equipment
and the Radio Frequency shielded room of a Medical Electrical
system for magnetic resonance imaging, where the intensity of
electromagnetic disturbances is high�
Cautions
A caution represents the possibility of damage to the equipment�
Never drop or insert any object into any opening
Do not immerse the device or allow any liquid to enter the enclosure

Table of Contents

Other manuals for Philips Respironics SimplyGo Mini

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Philips Respironics SimplyGo Mini and is the answer not in the manual?

Philips Respironics SimplyGo Mini Specifications

General IconGeneral
Battery Duration (Standard Battery)Up to 4.5 hours
Battery LifeUp to 4.5 hours with standard battery, up to 9 hours with extended battery
Oxygen Concentration87% to 96% at all settings
Pulse Dose Settings1 to 5
Recharge Time (Standard Battery)Approximately 4 hours
Recharge Time (Extended Battery)8 hours
Operating AltitudeUp to 10, 000 feet (3048 meters)
Sound Level43 dBA (at pulse dose setting 2)
Operating Temperature5°C to 40°C (41°F to 104°F)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Altitude RangeUp to 10, 000 feet (3048 meters)
Weight5 lbs (2.3 kg) with standard battery
Humidity Range15% to 95% non-condensing