Page #18 background imageLoading...
Page #18 background image
15
SimplyGo Mini User Manual
English
Operating the SimplyGo Mini Device
Power Options
Warning: Do not use the device without the battery installed and operating�
To run the device on battery power, make sure the battery is properly
inserted and suciently charged� (The battery should be fully
charged the rst time you use it�)
To run the device using AC power, rst make sure you have a
battery installed� Then, follow these steps:
1� Connect the output cable of the AC Power Supply to the
SimplyGo Mini power input connector, aligning the green dots
on the power cord and device as shown below
2� Connect the AC Power Cord’s connector into the AC power
supply
3� Connect the AC Power Cord’s plug into an AC outlet installed to
meet national or regional electrical code�
To run the device using DC power from an automobile or other
motorized vehicle, make sure the battery is installed� Start the vehicle
and connect one end of the DC Power Cord to the devices power
inlet and the other end into the vehicles DC electrical outlet�
SimplyGo Mini Power Cord Connection
When connecting the SimplyGo Mini
device to either an AC or DC power supply:
1� Align the green dot indicators
on the power cord�
2� Insert the cord connection
into the device as shown in
the illustration�
Note: DC power provided by the DC
Power Supply will also charge the battery when the device is turned o
or is running on setting 1, 2, or 3� It may not charge the battery when
the device is running on setting 4 or 5� Charging status can be veried
with the battery icon on the Home Screen�
Green Dots

Table of Contents

Other manuals for Philips Respironics SimplyGo Mini

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Philips Respironics SimplyGo Mini and is the answer not in the manual?

Philips Respironics SimplyGo Mini Specifications

General IconGeneral
Battery Duration (Standard Battery)Up to 4.5 hours
Battery LifeUp to 4.5 hours with standard battery, up to 9 hours with extended battery
Oxygen Concentration87% to 96% at all settings
Pulse Dose Settings1 to 5
Recharge Time (Standard Battery)Approximately 4 hours
Recharge Time (Extended Battery)8 hours
Operating AltitudeUp to 10, 000 feet (3048 meters)
Sound Level43 dBA (at pulse dose setting 2)
Operating Temperature5°C to 40°C (41°F to 104°F)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Altitude RangeUp to 10, 000 feet (3048 meters)
Weight5 lbs (2.3 kg) with standard battery
Humidity Range15% to 95% non-condensing

Related product manuals