User’s Manual of IGS-604HPT-M12
Built-in Unique PoE Functions for Surveillance Management
As a managed PoE Switch for surveillance network, the IGS-604HPT-M12 features the following intelligent PoE management
functions:
PD Alive Check
Scheduled Power Recycling
SMTP/SNMP Trap Event Alert
PoE Schedule
Intelligent Powered Device Alive Check
The IGS-604HPT-M12 can be configured to monitor a connected PD (Powered Device) status in real time via ping action. Once
the PD stops working and it is without response, the IGS-604HPT-M12 will resume the PoE port power and bring the PD back to
work. It will greatly enhance the network reliability through the PoE port resetting the PD’s power source, thus reducing
administrator management burden.
Scheduled Power Recycling
The IGS-604HPT-M12 allows each of the connected PDs to reboot at a specified time each week. Therefore, it will reduce the
chance of PD crash resulting from buffer overflow.