Page #332 background imageLoading...
Page #332 background image
User’s Manual of IGS-604HPT-M12
332
4.17 Loop Protection
This chapter describes enabling loop protection function that provides loop protection to prevent broadcast loops in Industrial
Managed Switch.
4.17.1 Configuration
This page allows the user to inspect the current Loop Protection configurations, and possibly change them as well; screen in
Figure 4-17-1 appears.
F
igure 4-17-1: Loop Protection Configuration Screenshot
The page includes the following fields:
General Settings
Object Description
Contro
ls whether loop protections is enabled (as a whole).
ï‚· Enable Loop
Protection
T
he interval between each loop protection PDU sent on each port. valid values
are 1 to 10 seconds.
ï‚· Transmission Time
T
he period (in seconds) for which a port will be kept disabled in the event of a
ï‚· Shutdown Time