User’s Manual of MGSW-24160F
492
6.23 DIDO Command
Di_act
Description:
Digital input fuction and action configuration.
Syntax:
di_act [first|second] [1|2|3|4] [enable|disable]
Parameters:
<first >: Digital input/output 1
<second>: Digital input/output 2
(default: Set or show digital input/output first(1)/second(2) select)
<1>: System Log
<2>: Syslog
<3>: SNMP Trap
<4>: SMTP
(default: set or show digital input 1/2 action)
<enable>: Enable digital input1/2 function
<disable>: Disable digital input1/2 function
(default: Set or show digital input/output/fault alarm 1/2 status)
Example:
Enable Digital input 1 and enable acion to System log.
SWITCH/ >dido di_act first 1 enable
Didital input1 action
System Log:enbale
Syslog :disable
SNMP Trap :disable
SMTP :disable
Di_desc
Description:
Set or show the system digital input1/2 description.