EasyManua.ls Logo

Planet MGSW-24160F - Do_Port_Alr; Do_Pwr_Alr

Planet MGSW-24160F
523 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User’s Manual of MGSW-24160F
495
<hightolow>: Trigger -> high to low
<lowtohigh>: Trigger -> low to high
(default: Set or show digital input/output 1/2 trigger)
Example:
Enable digital output function and set trigger condition.
SWITCH/>dido do_en first enable hightolow
Do_port_alr
Description:
Set or show the system digital output1/2 port alarm.
Syntax:
dido do_port_alr [first|second] [<port_list>]
Parameters:
<first >: Digital input/output 1
<second>: Digital input/output 2
(default: Set or show digital input/output first(1)/second(2) select)
<port_list>: Port list or 'all', default: All ports
Example:
Set digital output port alarm.
SWITCH/>dido do_port_alr first all
SWITCH/>dido do_port_alr first 1,3,5
SWITCH/>dido do_port_alr first 1-10
Do_pwr_alr
Description:
Set or show the system digital output1/2 power alarm.
Syntax:
dido do_pwr_alr [first|second] [dc1|dc2|ac] [enable|disable]
Parameters:
<first >: Digital input/output 1
<second>: Digital input/output 2
(default: Set or show digital input/output first(1)/second(2) select)