MacBAT 5 USER GUIDE. Version 1.0
This paragraph contains of full list of alarms with short description of appearing conditions:
Events typed in bold are the ones which are saved to Alarm LOG memory sector.
CODE
NAME
DESCRIPTION
0
Device startup
Device turned on initial startup, battery replacement, firmware upgrade or
malfunction.
1
System error
Device has detected the lack of P1 or T sensor
2
Calculation error
PTZ conversion is executed wrong plausible because of pressure out of range
3
AlgZ range
Gas composition parameters are out of range
4
P1 range
Pressure is out of range primary sensor
5
P2 range
Pressure is out of range
6
T range
Temperature is out of range
7
Qm range
Measurement flowrate is out of range
8
Tamb error
Ambient temperature sensor failure
9
Tamb range
Ambient temperature is out of range
10
Battery low
Battery level is below 10%
11
Ext. supply off
External power supply source has been disconnected
12
Ext. supply low
Fluctuations of connected power supply source possible that not compatible unit is
connected different than INT-S3 or supplied on the desk from USB 5V or another
common power supply
13
Keyboard error
Malfunctioning of the keyboard device checks the keys status periodically
14
Software update
Device firmware has been updated
15
Data update
Device data has been changed Modbus maps
16
Data erased
Erasing of the device
17
AlarmLOG full
Alarm LOG is filled up to 97% - requires confirmation of the alarm
18
Case open
Device case is opened
19
Intrussion attempt
5 unsuccessful attempts of login with wrong password. Lockdown of the device COM
ports for 15 minutes
20
Login
User logged in using keyboard