H-4
MacBAT 5 – USER GUIDE. Version 1.0
This paragraph contains of full list of alarms with short description of appearing conditions:
Events typed in bold are the ones which are saved to Alarm LOG memory sector.
Device turned on – initial startup, battery replacement, firmware upgrade or
malfunction.
Device has detected the lack of P1 or T sensor
PTZ conversion is executed wrong – plausible because of pressure out of range
Gas composition parameters are out of range
Pressure is out of range – primary sensor
Temperature is out of range
Measurement flowrate is out of range
Ambient temperature sensor failure
Ambient temperature is out of range
Battery level is below 10%
External power supply source has been disconnected
Fluctuations of connected power supply source – possible that not compatible unit is
connected – different than INT-S3 or supplied on the desk from USB 5V or another
common power supply
Malfunctioning of the keyboard – device checks the keys status periodically
Device firmware has been updated
Device data has been changed – Modbus maps
Alarm LOG is filled up to 97% - requires confirmation of the alarm
5 unsuccessful attempts of login with wrong password. Lockdown of the device COM
ports for 15 minutes
User logged in using keyboard