EasyManua.ls Logo

Plum MacBAT 5 - Compressibility Factor Calculation

Plum MacBAT 5
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E-6
MacBAT 5 USER GUIDE. Version 1.0
Gas composition and algorithm settings can be uploaded to EVC through the keyboard.
To change the algorithm of compressibility factor calculation:
Go to Main menu by pressing enter
Navigate to menu Gas and conversion Algorithm
Press enter on parameter ConfAlgZ to choose one of available algorithms
Available options:
SGERG-88
AGA8-G1
AGA8-G2
AGA NX19-mod
AGA8-92DC
K1=const.
Every algorithm require setting gas composition in a next step. All of them except AGA8-92DC require basically simplified gas composition.
If there is no simplified gas composition for each of them it is possible to use full gas composition instead if provided.
In order to switch the gas composition from simplified to full it is necessary to perform action:
Go to Main menu by pressing enter
Navigate to menu Gas and conversion Algorithm
Press enter on parameter ConfSGS to change the value
Available options:
Simpl. converter will be using simplified gas composition for calculations
Full comp. converter will be using full gas composition for calculations

Table of Contents