E-5
MacBAT 5 USER GUIDE. Version 1.0
Device allows for change of the registration period of the samples in the memory available range is from 1 to 60 minutes. More frequent
saving data shorter horizon of data storage in the memory. Another important parameters are gas day start and gas month start.
To change the registration data settings:
Go to Main menu by pressing enter
Navigate to menu Data Configuration Basics
Press enter on parameter to change its value
Available options:
Dtau samples registration period in the device memory, from 1 to 60 minutes
BillingHour hour of gas day start. By default 6:00
BillingDay day of gas month start. By default 1 1