B-6
MacBAT 5 – USER GUIDE. Version 1.0
Modem battery
Voltage: 3,6V
General capacity: 17Ah
Type: SAFT LS33600 – environmental temperature range available - -25 to 70 C degrees
Type: EVE ER34615 – environmental temperature range available - -25 to 50 C degrees
Battery amount: 2 to supply internal modem
Estimated lifetime: 5 years on 2 batteries, assuming:
• Three commucations per day, 5-minutes long each
• GSM signal level CSQ=20
• Ambient temperature 21°C
Backup battery
Voltage: 3,6V
General capacity: 1,2Ah
Type: SAFT LS14250, ½-AA size
Battery amount: 1
Estimated lifetime: 2 weeks
External power supply source
Dedicated safety barrier PLUM INT-S3 with following features:
• Ex classification II (2) G [Ex ib Gb] IIA
• Power supply source for MacBAT 5 – U
IN
=5,7V
• Enabling EVC functionalities requiring external power supply: frequency mode of digital output,
1s measurement cycle, HF pulse inputs
• Safety barrier for signals from outside of the hazardous zone
o RS485 port separation – enabling the transmission from equipment installed out of the
Ex Zone
o Digital outputs separation – transmitting signals from MacBAT 5 digital outputs to
automatic systems outside the Ex Zone
• Powering of the INT-S3 interface – 10,5-30V DC
INPUTS AND OUTPUTS
Digital inputs
• 6 Ex digital inputs – to cooperate with Potential-free junctions, shared with:
o 2 LF inputs, frequency 0÷60Hz, reed contact, WIEGAND
o 1 TS tamper protection switch (closed by default)
• 2 Ex digital inputs, NAMUR type, shared with:
o 2 HF inputs, frequency 0÷5000Hz EN60947-5-6, a possibility of temporary work on
battery
o 1 ENCODER (NAMUR type)
• 1 SCR ENCODER

Table of Contents