Comments, InformationIndications
7 Bridging over settling time
CAUTION! When the settling in stage is by--passed,
the display and all connected course receivers
indicate
that the course data is usable, even though there
may
be significant
deviations.
FOR SERVICE PURPOSES ONLY
Switch B 37 (DIP switch)
12345678
OPEN
Example:
B38
1X
B39
After the DIP switch is set into zero position
the settling stage is by--passed