-- Push the components of the screw fastening over the cable.
It is essential to follow the sequence (as shown in Figure 3).
-- Check the cone and the mating piece of the earthing insert for corrosion and
if necessary remove corrosion with an emery cloth.
-- Push the mating piece of the earthing insert to the end of the cable sheath.
-- Push the cone inside the screening and against the mating piece. Ensure
that the screening is evenly distributed over the cone (see Figure 3).
Wall an DIN cap
Screening
Earthing insert
-- Cone
-- Mating piece
Seal
+ Strain relief
Washer
Counter nut
Figure 3: Creating the cable connection