Installation Requirements
Environment
1. Temperature Range: 10 °C to 32 °C (50 °F to 90 °F)
2. Humidity Range: 15% to 80% RH
3. Ambient Illumination: Less than 1,500 lux (do not expose to direct sunlight.)
4. Ventilation: Room air should turn over at least 30 m
3
/hr/person
5. Ambient Dust: Less than 0.10 mg/m
3
(2.7 x 10
-6
oz/yd
3
)
6. Avoid areas exposed to sudden temperature changes:
Areas directly exposed to cool air from an air conditioner.
Areas directly exposed to heat from a heater.
7. Do not place the machine where it will be exposed to corrosive gases.
8. Do not install the machine at any location over 2,000 m (6,500 ft.) above sea level.
9. Place the main machine on a strong and level base. Inclination on any side should be no more than
5 mm (0.2").
10. Do not place the machine where it may be subjected to strong vibrations.
Machine Level
Front to back: Within 5 mm (0.2") of level
Right to left: Within 5 mm (0.2") of level
Minimum Space Requirements
Place the main machine near the power source, providing clearance as shown: