Service Program Mode Tables
Service Table Key
Notation What it means
[range / default / step]
Example: [–9 ~ +9 / +3.0 / 0.1 mm step]. The setting can be adjusted in
the range ±9, value reset to +3.0 after an NVRAM reset, and the value can
be changed in 0.1 mm steps with each key press.
italics Comments added for reference.
DFU Denotes “Design or Factory Use”. Do not change this value.
Japan Only The feature or item is for Japan only. Do not change this value.
NIA No Information Available (April 2006)
Service Tables
SP1-xxx: Feed
1001
Subscan Reg Adj Leading Edge Registration
Adjusts the printing leading edge registration using the trimming area pattern (SP2-902-3, No.
10).
[+9 ~ –9 / 3.0 / 0.1 mm]
Use [./] to toggle between + and – before entering the value. Specification: 3 ±2 mm
1002
Side-to-Side Reg Side-to-Side Registration
Adjusts the printing side-to-side registration from the 3rd paper feed station using the trimming
area pattern (SP2-902-3, No.10). Tray 3, Tray 4 are for the optional Paper Feed Unit.
Use the [./] key to toggle between + and – before entering the value. Specification: 2 ±1.5 mm
001 Tray-1 [–9 ~ +9/ +3.0 mm / 0.1 mm step]
002 Tray-2 [–9 ~ +9/ +3.0 mm / 0.1 mm step]
003 Tray-3 [–9~ +9/ +2.0 mm / 0.1 mm/step]
5. Service Tables
186