Memory Clear: SP5801
Executing Memory Clear resets all the settings stored in the NVRAM to their default settings, except the
following:
SP5811-1: Machine serial number
SP5907: Plug & Play Brand Name and Production Name Setting
• This procedure restores all SP code settings to their factory default settings.
• Before clearing all settings in memory with SP5801, print an SMC report with SP5990. You may
need this for reference to restore previously adjusted settings.
1. Push and together, hold down for over 5 seconds, release and then press [#Enter].
2. Press or to display “2.Engine”.
3. Press [#Enter].
4. Press or to display “5.Mode” then press [#Enter].
5. Press or to display “SP5801/Memory Clear” then press [#Enter].
6. With “Clear All” displayed, press [#Enter], then press [#Enter] again to execute.
<All>
result=OK
Here is a summary of all the settings.
No. Item What It Initializes
001 All All items in this table
002 Clear Engine All settings set for engine and processing
003 SCS System Control Service (ROM update information)
004 IMH Image Memory Handler
005 MCS
008 PRT Printer defaults
010 WebService Netfile (NFA) management files, thumbnails, the Job login ID.
5. Service Tables