2. Two snap rings [A] ( x 2).
3. Charge roller holder [B]
4. Charge roller [C]
• Do not touch the charge roller.
5. Cleaning roller [D].
6. SP Adjustment:
Charge Roller Bias Adjustment 2001-01
Set to the standard value
(–1,480 V) to ensure carrier is not
attracted to the drum.
ID Sensor Pattern 2001-02 -200 V
Image Transfer Current - Image Face 2301 01
Set to the default settings.
Image Transfer Current - Image Back 2301 02
Image Transfer Current - Lead Edge Face 2301 03
Image Transfer Current - Image Face By-pass 2301 04
Image Transfer Current - Lead Face By-pass 2301-05
3. Replacement and Adjustment
86