SERVICE PROGRAM MODE
B089/B093 4-36 SM
5302 2* Set Time
Adjusts the RTC (real time clock) time setting for the local time zone.
[–1440~+1440 / see below / 1 min./step]
NA: -300 (New York)
EU: +60 (Paris)
Asia: +480 (Hong Kong)
Example: For Japan (+9 GMT), enter 540 (9 hours x 60 min.)
User Code Count Clear 5404
Clears the counts for the user codes assigned by the key operator to restrict the
use of the machine.
5501* PM Alarm
5501 1 PM Alarm Interval
Sets the PM interval.
The value stored in this SP is used when the value of SP55012 is “1”.
[0 ~ 255 / 0 / 1 k copies/step]
5501 2 Original Count Alarm DFU
Selects whether the PM alarm for the number of scans is enabled or not.
If this is “1”, the PM alarm function is enabled.
[0 = No / 1 = Yes]
5504* Jam Alarm
Sets the alarm to sound for the specified jam level (document misfeeds are not
included). RSS use only
[0~3 / 3 / 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
Error Alarm Setting 5505*
Sets the error alarm level. Japan only DFU
[0~255 / 50 / 100 copies per step]