SERVICE PROGRAM MODE
B089/B093 4-38 SM
5508* CC Call
5508 1 Jam Remains
Switches the control call on/off for an unattended jam. Japan Only
0: Off, 1: On
If you select “1”, the alarm sound if a jam is left unattended for 15 minutes.
5508 2 Continuous Jams
Switches the control call on/off for the occurrence of consecutive jams. Japan
Only
0: Off, 1: On
If you select “1”, the alarm will sound if 5 consecutive jams occur in the copier.
5508 3 Continuous Door Open
Switches the control call on/off for the cover open alarm. Japan Only
0: Off, 1: On
If you select “1”, the alarm will sound if the door remains open for 15 minutes.
5508 4 Low Call Mode
Selects whether or not the new CC call. Japan Only
0: Previous Mode, 1: New Mode
5508 11 Jam Details: Time Length
This SP is effective when the value of SP5508-4 is “1”. Japan Only
[3 ~ 30 / 10 / 1 min/step]
5508 12 Jam Details: Continuous Count
This SP is effective when the value of SP5508-4 is “1”. Japan Only
[2 ~ 10 / 5 / 1 time/step]
5508 13 Door Open: Time Length
This SP is effective when the value of SP5508-4 is “1”. Japan Only
[3 ~ 30 / 10 / 1 min/step]
5508 21 Jam Operation: Time Length
This SP is effective when the value of SP5508-4 is “1”. Japan Only
0: Auto Call, 1: Alarm
5508 22 Jam Operation: Continuous Count
This SP is effective when the value of SP5508-4 is “1”. Japan Only
0: Auto Call, 1: Alarm
5508 23 Door Operation: Time Length
This SP is effective when the value of SP5508-4 is “1”. Japan Only
0: Auto Call, 1: Alarm