SERVICE PROGRAM MODE
B089/B093 4-110 SM
4. Press the number for the item that you want to initialize. The number you select
determines which application is initialized. For example, press 1 if you want to
initialize all modules, or select the appropriate number from the table below.
No. What It Initializes Comments
1 All modules Initializes items 2 ~ 12 below.
2 Engine
Initializes all registration settings for the engine and
process settings.
3
SCS (System Control
Service)/SRAM
Initializes default system settings, CSS settings,
operation display coordinates, and ROM update
information.
5
MCS (Memory Control
Service)
Initializes the automatic delete time setting for
stored documents.
6 Copier application Initializes all copier application settings.
7 Fax application
Initializes the fax reset time, job login ID, all TX/RX
settings, local storage file numbers, and off-hook
timer.
8 Printer application
Initializes the printer defaults, programs registered,
the printer SP bit switches, and the printer CSS
counter.
9 Scanner application
Initializes the scanner defaults for the scanner and
all the scanner SP modes.
10 Network application
Deletes the network file application management
files and thumbnails, and initializes the job login ID.
11
NCS (Network Control
Service)
Initializes the system defaults and interface settings
(IP addresses also), SmartNetMonitor for Admin,
WebStatusMonitor settings, and the TELNET
settings.
12 R-FAX
Initializes the job login ID, SmartNetMonitor for
Admin, job history, and local storage file numbers.
14 Clear DCS Settings
Initializes: SP5845 (All), SP5860 (All), SP5861
(All), SP5863, registered scanner documents and
subjects.
15 Clear UCS Settings Initializes: SP5846 (All), SP5801 15
5. Press Execute and turn the main switch off and back on.
6. Download the NVRAM data from a flash memory card (! NVRAM Data