CORRECTING THE IMAGES
SM 6-49 B089/B093
Replacement
Adjustment
Procedure B:
Fig. 3 Fig. 4
1. Remove the ADF, rear cover, scanner left cover, and scanner rear cover.
2. Check the height difference between the hinge bracket and scanner housing.
3. If this difference is 0.5mm or more, please do one of the following. This is
necessary since it has been confirmed that skewing occurs when the hinge
bracket is this much lower than the scanner housing:
1) Add a spacer (t = 0.5 to 0.8) between the hinge bracket (mainframe) and
ADF left hinge, in order to raise the height of the left side of the ADF, OR:
2) Adjust the stepped height difference between the hinge bracket and scanner
housing until it is within 0±0.3mm.