17 January, 2003 SC TABLE
4-19
SC No. Item Definition Possible Cause
Related
SCs
Troubleshooting Procedure Type
SC
392-
001
Air pump motor
error
391-001: MY
391-002: CK
Three consecutive errors are
detected in motor-driver-signal
samples. The samples are
collected every 0.01 second.
Damaged cable
Short circuit
Defective motor
1. Turn the main switch off and on.
2. Replace the air pump.
3. Check the circuit.
SC
440-
001
Drum motor
error
440-001: Black
440-002: Color
No drum gear position sensor
signal is detected within 0.7
second (185 mm/s), 1.0
second (125 mm/s), or 2.0
seconds (62.5 mm/s).
Defective PCU
Defective drum motor
Defective drum gear
position sensor
1. Turn the main switch off and on.
2. Check and/or replace the PCU.
3. Check and/or replace the sensor.
SC
460-
001
Thermistor 1
error (open
circuit)
When the temperature
detected by thermistor 1,
which is at the left (fusing unit)
side of the laser optics unit, is
less than -30°C for 10 seconds
consecutively, the BCU
determines that the circuit is
opened and displays this SC
code.
Thermistor 1
defective
Cable connection
error
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.
SC
460-
002
Thermistor 1
error (short
circuit)
When the temperature
detected by the thermistor 1,
which is at the left (fusing unit)
side of the laser optics unit, is
higher than 70°C for 10
seconds consecutively, the
BCU determines that the
circuit is shorted and displays
this SC code
Thermistor 1
defective
Cable connection
error
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.