EasyManua.ls Logo

Ricoh J-P2 - Page 142

Ricoh J-P2
419 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC TABLE 17 January, 2003
4-20
SC No. Item Definition Possible Cause
Related
SCs
Troubleshooting Procedure Type
SC
461-
001
Thermistor 2
error (open
circuit)
When the temperature
detected by the thermistor 2,
which is at the right (paper
feed section) side of the laser
optics unit, is less than -30°C
for 10 seconds consecutively,
the BCU determines that the
circuit is opened and displays
this SC code.
Thermistor 2
defective
Cable connection
error
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.
SC
461-
002
Thermistor 2
error (short
circuit)
When the temperature
detected by the thermistor 2,
which is at the right (paper
feed section) side of the laser
optics unit, is higher than 70°C
for 10 seconds consecutively,
the BCU determines that the
circuit is shorted and displays
this SC code
Thermistor 2
defective
Cable connection
error
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.
SC 471
Transfer belt
H.P. error
The transfer belt HP sensor
signal does not change from
Low to High (home position) or
vice versa 1 second after the
transfer belt contact motor
turns on.
Transfer belt unit not
set properly
Defective transfer belt
H.P. sensor and/or
transfer belt sensor
Defective transfer belt
contact motor
Transfer belt unit
problem
1. Turn the main switch off and on.
2. Reset the transfer belt unit.
3. Clean or replace the transfer belt
sensor.
4. Replace the transfer belt contact
motor.
5. Check the contact and release
mechanism of the transfer belt unit.

Table of Contents