Technical Bulletin PAGE: 4/7
Reissued: 20-Apr-15
Modified Points or Symptom Corrected
Specification Changes
1. The following SPs to prevent condensation were added under SP1945 "Set
Cooling Operation":
・ SP1945-016
When the temperature is lower than the value defined in this SP, the anti-
condensation function turns ON.
・ SP1945-017
The rotation speed of the fans can be adjusted in this SP, either full-speed
or half-speed. The rotation of the fans increases the guide plate
temperature and prevents condensation.
・ SP1945-018
This SP specifies ON("1") or OFF("0") of the anti-condensation function.
2. The following SP for adjusting the sub scan registration was added.
・ SP1-501-001
* Please see RTB #RD074022a for details.
3. The default values for the following SPs were modified for better image
quality.
- SP1984-104 170->180
- SP1984-125 165->180
- SP1984-110 170->160
- SP1984-117 170->160
Engine and System/Copy must be upgraded concurrently.
Engine 1.56.1:04 (D0745404D)
System/Copy 1.06 (D0745773E)
(NOTE: Fiery version must be 1.1 or 1.2)
Plockmatic and GBC Punch are supported from the following ver,
Engine 1.56.1:04 (D0745404D)
System/Copy 1.06 (D0745773E)
Fiery version 1.2
Finisher SR5040/SR5030 01.040.01(D5125620D)
Specification Changed;
1. SP1945-013 default:0 (0:Normal Speed, 1:Half Speed)
2. The following unused SP were deleted.
- SP1002-001-003
- SP1020-001-003
- SP2823-001-007
- SP2824-001-007