Symptom Corrected;
1. Black registration is misaligned when MUSIC is processed if the subscan
magnification correction has been adjusted.
If SC occur when paper feeds in Ring-Binder or Multi-Folding Unit, the machine
stops until the power is cycled.
Symptoms Corrected:
[Symptom]
When copying a document consisted of full color and mono color originals
using the ACS, the density of the first few mono color outputs appear light.
[Cause & Solution]
Paper transfer current is too high for the mono-color images because the ACS
runs on color mode.
Software has been modified to set the optimum paper transfer current
applicable for both color and mono-color originals.
The following peripherals are supported starting from this version:
- Buffer Pass Unit Type 5010
- Trimmer Unit TR5040
- Cover Interposer Tray CI5020
- High Capacity Stacker SK5020
- Ring Binder RB5010
Please make sure the firmwares are updated to the versions listed below for
new site installations.
Bug fixes hereafter will also be based on this combination.
[Mainframe]
Program Name Version Program No.
Engine 1.54:04 D0745404C
TDCU 01.03:54 D0745528C
Web Uapl 1.02 D0745778B
Web Support 1.05 D0745777B
Language 1.02 D0746890A
OpePanel_USA 1.05 D0746885B
Opepanel_EUR 1.05 D0746886B
Sysytem 1.05 D0745773D
[Fiery Server]
System Software Version 1.1
User Software Version 1.1
[Update Procedure]
1. Fiery Server
Step1-1.
<For New Site Installations>
Check the Fiery software version described on the label of the System software
accessory DVD.
<For Existing Sites>
Check the Fiery software version on the FieryDriven screen.