EasyManua.ls Logo

Ricoh Taurus-C1a - Page 156

Ricoh Taurus-C1a
568 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Bulletin PAGE: 2/9
Model: Taurus-C1/P1 (D074/D075/M044) Date: 15-Feb-12 No.: RD074045
NOTE: A USB converter is not required if the PC is equipped with a serial port.
Basic Idea of Log Capturing
The Taurus-C1/P1 engine runs on one CPU.
IMPORTANT: All the logs from the beginning of the job until the symptom occurrence is
required for log analysis.
Overall Workflow
1. Connect the debug cable.
2. Set up Tera Term and start the log capturing. (Tera Term is free software.)
3. Start the job.
4. Wait until the expected symptom occurs.
5. Stop the log capturing process.
6. Disconnect the cable.
Connecting the Debug Cable
1. Remove the screws to open the rear boxes. (x3)
2. Swing open the rear box [A] in the direction of the arrow.
3. Confirm the location of the IOB/BCU Board.
This photo shows the IOB Board. The BCU is behind the IOB Board.

Table of Contents

Related product manuals