Technical Bulletin  PAGE: 2/4 
Reissued:30-Apr-13 
Model: Taurus-C1a/C1b (D074/D075) Date: 14-Mar-12 No.: RD074053c 
 
 
 
 
5.  Remove the sensor bracket [D] (Screw x1). 
 
 
 
6.  Carefully move the belt [A] to the non-operator side until the sensor [B] is uncovered. 
Note 
It is recommended to wear gloves when moving the ITB. 
Do not further move the belt once the sensor is uncovered.  Doing so could damage the belt. 
[A] 
[B] 
[D]