Technical Bulletin PAGE: 4/4
Reissued:30-Apr-13
Model: Taurus-C1a/C1b (D074/D075) Date: 14-Mar-12 No.: RD074053c
8. Confirm the sensors are clean using a flashlight. Dust on the sensor is hard to detect in room
light.
9. Reinstall the unit
10. Turn the machine on. Wait until the machine is ready.
11. Execute SP2-912-001 (Encoder Sn:Adj Light: Adj Light Amt).
12. Turn the main switch off and then on.
13. Execute SP2-914-001 (Encoder Sn:Get 1stPhase: Get Phases: Execute All).
14. Turn the main switch off and then on.
15. Check the value of SP2-915-001 (Encoder Sn Ctrl Condition: Scale FB Control Enable)
If the value is “1”, the feedback control is properly turned on.
If the value is “0,” repeat the sensor cleaning procedure.
16. Execute SP3011-4 (Manual ProCon :Exe: Full MUSIC).
17. Exit the SP mode to complete the procedure.