EasyManua.ls Logo

Ricoh Taurus-C1a - Page 281

Ricoh Taurus-C1a
568 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T
echnical
B
ulletin PAGE: 4/6
Model:
Taurus-C1a/C1b/P1 (D074/D075/M044)
Date:
13-Jun-12
No.:
RD074074
2. Attaching the new mylar D0742477
2-1. Peel off the 2 mylars and
clean the surface with
solvent.
NOTE: Work carefully to prevent
solvent from adhering to areas other
than the surface of the stay, for
instance, the urethane sponge.
a)
b)
c)
2-2. Attach the D0742477.
a) Mark a reference point at
8mm from the edge of the
stay.
b) Draw a line from the reference
point leaving 9mm of space at
the bottom.
c) Attach the D0742477 (2pcs)
on both sides so that they are
inside the reference line.
NOTE: Confirm clean attachment;
no-air bubbles, peel-offs.
8mm
9mm
Attach D0742477 to
the inside of the line.

Table of Contents

Related product manuals