T
echnical
B
ulletin PAGE: 17/20
Reissued:18-Feb-13
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
08-Jan-13
No.: RD074097c
49: Txt Ppr: Ppr Trns Isolatn Voltag: Side 2
Adjust the separation voltage for paper transfer applied to side 2 when the profile of a textured paper (paper
displayed as [Txt Textured***-*** gsm ***] in the paper library) is registered as a custom paper.
Press [+] or [-] to adjust the voltage.
Setting Item Max. Value Min. Value Step Unit
Txt Ppr: Ppr Trns Isolatn Voltag: Side 2 12 0 0.1 kV
To cater for the additional adjustment functions, change the numbering of the items in "Custom Paper
Settings for Administrators" as follows:
Item Old numbering New numbering
Fusing Heat Roller Temperature Adj 44 50
Fusing Pressure Roller Temperature Adj 45 51
Fusing Nip Width Setting 46 52
Paper Feed Interval Setting 47 53
Reduce Initial CPM: Low Temp. Envrnmt 48 54
Reduce Initl CPM: Norml/High Temp Env 49 55
Adjust Cleaning Web Motor Interval 50 56
Decurler Feed Speed Adj: Curl Adj Off 51 57
Decurler Feed Speed Adj: Curl Adj Weak 52 58
Decurler Feed Speed Adj: Curl Adj Strg 53 59
Adjust Z-fold Position 1 54 60
Adjust Z-fold Position 2 55 61
Half Fold Position: Single-sheet Fold 56 62
Letter Fold-out Posn 1: Single-sheet Fld 57 63
Letter Fold-out Posn 2: Single-sheet Fld 58 64
Letter Fold-in Posn 1: Single-sheet Fold 59 65
Letter Fold-in Posn 2: Single-sheet Fold 60 66
Double Parallel Fold Position 1 61 67
Double Parallel Fold Position 2 62 68
Adjust Gate Fold Position 1 63 69
Adjust Gate Fold Position 2 64 70
Adjust Gate Fold Position 3 65 71