T
echnical
B
ulletin PAGE: 4/4
Reissued:1-Oct-13
Model:
Taurus-C1a/C1b (D074/D075)
Date:
27-May-13
No.:
RD074104a
IMPORTANT
Make sure to note the following points to prevent scratches on the surface of the
development roller.
¾ DO NOT push and pull the tool.
¾ DO NOT press the tool against the dev roller with your thumb.
¾ DO NOT touch the roller with your fingers.
5. After sliding the tool across the doctor gap, remove the tool from the corner without the
tab.
NOTES
z For a thorough cleaning of the doctor gap, it is recommended to repeat the cleaning
procedure 2 ~ 3 times.
z The tool can be used many times. Use the other end of the tool or replace with a new
tool when the tab becomes worn and jaggy.