Technical Bulletin PAGE: 10/58
Model: Taurus-C1 / P1 Date: 21-Oct-11 No.: RD074026
<Main Machine \ Installation: Power Off \ Attention Light >
Screws for fixing the Attention Light were changed.
Before the Revision After the Revision
1. The attention light is installed on the top rear edge
[A] with accessory screws (
x3 M4x8).
1. The attention light is installed on the top rear edge
[A] with accessory screws ( x3 M4x6).
• The three screws must be removed from their
holes (these screws are not accessories).
<Main Machine \ Installation: Power Off \ Install Operation Panel: Standard
Installation >
Instructions were revised accordingly with the change in screw type.
Before the Revision After the Revision
13. Fasten the back of the operation panel [A] to the
mounting bracket [B] (
x4).
• You will need a short screwdriver to attach the
screw at
.
13. Fasten the back of the operation panel [A] to the
mounting bracket [B] (
x4 M4x6). You will
need a short screwdriver to attach the screw at
.
• You must use the M4x6 screws to fasten the
operation panel at this step. If you use the
longer screws (M4x8) they could touch and
damage the operation panel board.