Technical Bulletin PAGE: 34/58
Model: Taurus-C1 / P1 Date: 21-Oct-11 No.: RD074026
4. Use a small brush to apply FLUOTRIBO MG Grease to the flanges at . Never apply grease to the outer
rim of the flange at
.
5. After lubricating a flange, inspect the rim.
6. If you see grease on the rim of a flange [A], rub the rim of the flange [B] against the flat surface of a clean
dry cloth to remove the grease.
Apply an appropriate amount of FLUOTRIBO MG Grease to the flange referring to the pictures above.
The left picture above [A] shows the minimum amount and right picture above [B] shows the maximum
amount.
• If applied grease is not enough comparing with the left picture [A], the fusing belt may shift on the
flange rib and cause the fusing belt a malfunction finally.
• If applied grease is much more comparing with the right picture [B], the hot roller may get excessive
grease and cause the hot roller a malfunction finally.