Technical Bulletin PAGE: 37/58
Model: Taurus-C1 / P1 Date: 21-Oct-11 No.: RD074026
Indication of the sensor position was corrected.
Before the Revision After the Revision
< Duplex Motors and Rollers >
Corrupted image of the paper path was revised.
Before the Revision After the Revision
6. Troubleshooting
< SC Tables \ SC200: Image Writing >
SC206: False description was corrected.
Before the Revision After the Revision
After the C, K polygon motor turned on, or
within 10 sec. after the rpm’s changed,
the motor did not achieve motor lock
(READY) status.
After the Y,M polygon motor turned on, or
within 10 sec. after the rpm’s changed,
the motor did not achieve motor lock
(READY) status.
SC208: False description was corrected.
Before the Revision After the Revision
The C,K polygon motor left the lock status
once after the motor achieved regular
rotation speed.
The Y,M polygon motor left the lock status
once after the motor achieved regular
rotation speed.