Technical Bulletin PAGE: 38/58
Model: Taurus-C1 / P1 Date: 21-Oct-11 No.: RD074026
SC210: Missing description was added.
Before the Revision After the Revision
• Cycle the machine off/on
• Laser unit defective
• Cycle the machine off/on
• CK Laser unit defective
SC220, SC222, SC224, SC226: False description was corrected.
Before the Revision After the Revision
50 ms (50 ms x2) 100 ms (100 ms x2)
SC240: False description was corrected.
Before the Revision After the Revision
• YM laser unit defective • CK laser unit defective
False descriptions were corrected.
Before the Revision After the Revision
SC260 C Laser Thermistor Error (K)
SC262 C Laser Thermistor Error (C)
One of the following occurred: ・
The reading of the thermistor in
the CK laser unit was less than
10°C (50°F), indicating that
the thermistor has disconnected.
・ The reading of the thermistor
in the CK laser unit was more
than 80°C (176°F), indicating
that the thermistor has shorted
out.
・ Cycle the machine off/on
・ IOB harness loose,
disconnected, broken, defective ・
CK laser unit defective
・ IOB defective
SC260 C Laser Thermistor Error (CK)
SC262 C Laser Thermistor Error (YM)
One of the following occurred:
・ The reading of the thermistor in
the CK or YM laser unit was less
than 10°C (50°F), indicating
that the thermistor has
disconnected.
・ The reading of the thermistor in
the CK or YM laser unit was more
than 80°C (176°F), indicating
that the thermistor has shorted
out.
・ Cycle the machine off/on
・ IOB harness loose, disconnected,
broken, defective ・ CK or YM laser
unit defective ・ IOB defective