6.3 Fault table
Fault description Cause Remedy Personnel
High noise generation/
knocking noises
Overload of the lifting
column, crooked spindle
deflects.
Contact RK Rose
+Krieger GmbH.
Assembly staff
Restricted lifting speed Motor faulty. Contact RK Rose
+Krieger GmbH.
Assembly staff
Lifting column does not
retract or extend evenly
Too much play between the
profiles due to wear on the
plastic sliding elements (as a
result of soiling or use of
chlorine cleaner).
Contact RK Rose
+Krieger GmbH.
Assembly staff
Lifting column does not
retract or extend
Motor, limit switch or inner
wiring faulty.
Contact RK Rose
+Krieger GmbH.
Qualified elect-
rician
Lifting columns have diffe-
rent extension heights
during synchronous opera-
tion
Electrical faults. Carry out an initialisation run.
Ä
Instructions for the con-
troller
Assembly staff
6.4 After maintenance and troubleshooting
Perform the following steps once maintenance and troubleshooting
are complete:
1. Check that all screw connections loosened previously are
secure.
2. Ensure that all tools, materials and other equipment used
have been removed from the work area.
3. Clean the work area and remove any escaped substances
such as liquids, processing material or similar products.
Maintenance and troubleshooting
After maintenance and troubleshooting
20.02.2019Lifting column Multilift I/Multilift II110