36 Rockwell Automation Publication 2198-RM002A-EN-P - October 2017
Chapter 2 Servo Drive and System Comparison
Table 11 - Kinetix 6000 Control and DC-bus Circuit Protection Specifications
Table 12 - Kinetix 6000 Input-power Circuit-protection Specifications
IAM Module
Cat. No.
Control Input Power DC-bus Power
Bussmann Fuse
(1)
(1) Use FNQ-R-7.5 circuit breaker for higher single -cycle inrush current capability. This is recommended when the continuous control-power current exceeds 3.0 A.
Allen-Bradley® Circuit
(2)
non-UL)
(2) Use 1492-SPM1D150 circuit breaker for higher single -cycle inrush current capability. This is recommended when the continuous control-power current exceeds 3.0 A.
Bussmann Fuse Mersen Fuse
(3)
(3) Mersen fuses were formerly known as Ferraz-Shawmut.
2094-BC01-MP5-S
FNQ-R-10 (10 A) or
FNQ-R-7.5 (7.5 A)
1492-SPM2D060 or
1492-SPM1D150
FWJ-20A14F DCT20-2 HSJ20
2094-BC01-M01-S
2094-BC02-M02-S FWJ-40A A70QS40-4 HSJ40
2094-BC04-M03-S FWJ-70A A70QS70-4 HSJ70
2094-BC07-M05-S FWJ-125A A70QS125-4 HSJ125
Kinetix 6000 Drives UL Applications IEC (non-UL) Applications
IAM Module
Cat. No.
Drive Voltage
(three-phase)
nom
Fuses (Bussmann)
Cat. No.
Miniature CB
Cat. No.
Motor Protection CB,
Self-protected CMC
Cat. No.
Molded Case CB
Cat. No.
Miniature CB
Cat. No.
Motor Protection CB
Cat. No.
Molded Case CB
Cat. No.
2094-BC01-MP5-S 360…480V AC
KTK-R-20 (20 A)
Class CC
1489-M3D300
140M-F8E-C32
–
1492-SPM3D300 1489-M3D300
140M-F8E-C32
–2094-BC01-M01-S 360…480V AC
KTK-R-20 (20 A)
Class CC
140M-F8E-C32 140M-F8E-C32
2094-BC02-M02-S 360…480V AC
KTK-R-30 (30 A)
Class CC
1489-M3D400 140M-F8E-C45 1492-SPM3D400 1489-M3D400 140M-F8E-C45
2094-BC04-M03-S 360…480V AC
LPJ-45SP (45 A)
Class J
––
140G-G6C3-C50
–––
140G-G6C3-C50
2094-BC07-M05-S 360…480V AC
LPJ-80SP (80 A)
Class J
140G-G6C3-C90 140G-G6C3-C90