EasyManua.ls Logo

Rohde & Schwarz SMB 100a - RF Phase; Phase - Menu

Rohde & Schwarz SMB 100a
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R&S SMB RF Phase
1407.0806.32 4.29 E-2
RF Phase
The phase of the RF output signal can be changed in the RF Phase menu.
Phase - Menu
The Phase menu is opened in the RF function block or using the MENU key under RF.
The phase of the output signal can be changed in the Phase Settings section (upper part of the group
menu).
The lower parts concern the frequency settings for the output signal and are described in the section
"RF Frequency", page 4.26
Delta Phase – RF Phase
Sets the phase of the RF signal. The current phase of the signal is
used as the reference. This function allows, for example, the phase of
the output signal to be synchronized with the phase of a signal from a
second signal generator.
Remote-control command:
SOUR:PHAS 10 DEG
Reset Delta Phase Display
– RF Phase
Resets delta phase value. The set phase is adopted as the new
current phase, i.e. the delta phase value is reset to 0.
Remote-control command:
SOUR:PHAS:REF

Table of Contents