57 / 291 - EN -
6.5.3.
Programming the “FULL” & “END” ramp rates
Programming a “FULL” heating or cooling ramp in the firing program:
Display Icon Meaning Description Remark
Pr. 1
Program number
Select the firing
program that is to be
changed.
See Section 6.4.1.
1
Indicator in the
segment display
Select the segment
with the heating ramp
to be changed into a
cooling ramp.
See Section 6.4.1.
150
Heating ramp
Cooling ramp
The ramp rate for the
heating or cooling ramp
is shown in the main
display.
Possible main display:
1°C/h-999°C/h
FULL
Heating ramp
Cooling ramp
Press or hold down
the
d
key until “FULL”
appears in the main
display.
“FULL” heats or cools as fast as
possible.
The “END” value is one step above
the ramp rate “999°C/h”.
*The keys
d
or
f
can also be held down for faster input.
Programming the “END” of a heating ramp or cooling ramp in the firing program:
Display Icon Meaning Description Remark
Pr. 1
Program number
Select the firing
program that is to be
changed.
See Section 6.4.1.
1
Indicator in the
segment display
Select the segment
with the heating ramp
to be changed into a
cooling ramp.
See Section 6.4.1.
150
Heating ramp
Cooling ramp
The ramp rate for the
heating or cooling ramp
is shown in the main
display.
Possible main display:
1°C/h-999°C/h