Reference
Modification-No.
- 0 -
Page
23
Date
1996 05 10
Install
914 F
WARNING: The maximum storage period is limited to 24 month!
Preservation for periods of longer than 24 months is only possible
after a written permission of BOMBARDIER-ROTAX. Should the
situation arise send engine for inspection to ROTAX.
NOTE: No trouble to put engine back into operation after preservation.
9.4) Protective covering
All openings are protected against ingress of contamination and dampness. It is
recommended not to remove these plugs until installation of the specific feed line.
NOTE: If the engine will be sent to the manufacturer or distributor reuse
transport equipment and replug openings.
List of protective covering:
exhaust socket:............................................. 1x cone plug
Air intake socket on turbo: ............................ 1x cover
connection for manifold pressure: ................ 1x cap
fuel pressure control (in-and outlet): ............. 1x each cap
oil supply and oil discharge: ......................... 1x each cap
oil return (turbo): ........................................... 1x cap
supply and discharge of coolant: .................. 1x each cone plug
propshaft on version F3: ............................... 1x disk plug
WARNING: Protective covering to be utilized for transport and at engine instal-
lation only. Before engine operation remove these protections.

Table of Contents

Other manuals for Rotax 914 F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 F and is the answer not in the manual?

Rotax 914 F Specifications

General IconGeneral
BrandRotax
Model914 F
CategoryEngine
LanguageEnglish

Related product manuals