Install
914 F
19.4.14)Battery
See Ill. 52.
ATTENTION: To warrant reliable engine start use a battery of at least 16
Ah capacity.
19.5) Internal consumer of electric power
WARNING: The power consumption of extra users has to be limited to the extent
that the internal need of power, e.g. for fuel pumps is always covered.
Refer to graph, current output over speed of the integrated generator
and the external alternator.
item current consumption
fuel pump (main)............................max. 3 A
fuel pump (stand by) ......................max. 3 A
TCU
(1
............................................max. 0,3 A
servo motor....................................max. 1 A
warning lamp
(2
..............................approx.0,25 A
caution lamp
(2
...............................approx.0,25 A
sum
(3
............................................ ~ 8 A
(1
internal power consumption, without servo motor and lamps
(2
standard value, actual value up to aircraft builder
(3
without electric starter and start relay