2. Explanation of Terms and Index
8-17
Term (in alphabetical
order)
The reagent in the retort is mixed with repeated pumped out/in.
The retort is pressurized and vacuumed repeatedly.
A spare power supply that supplies the power from the instrument to operate the
battery in the event of power outage or other power failure.
The retort is preheated for this time before cleaning.
Warm Water Flush is to wash away the precipitate build-up that forms in the tubing
when neutral buffered formalin is used.
A management method that can be set for managing solutions. A desired value
between 1 and 99 can be set.
"Station configurations, solution name lists, tissue processing programs, retort
cleaning programs, program name lists, tissue processing results, cleaning results,
solution exchange results, instrument settings, solution usage statuses, parts
usage statuses and error logs" are exported to the USB flash drive connected to
the instrument.
A management method that can be set for managing solutions. A desired number
of cassettes can be set between 1 and 9,999.
This filter is used to adsorb gases generating inside the instrument.
The interior of the retort is dried.
A password needed to use the instrument in day-to-day operations.
A method by which to manage solution exchange. Four methods are available:
"Runs/Days/Cassettes/NONE." Note that "Cassettes" cannot be set for cleaning
solution stations.
Operation to pump-in reagent to the retort when the instrument stops during tissue
processing, to protect the specimens being processed from becoming dry.
Number assigned to identify each tissue processing.
Solution is automatically transferred to the subsequent solution stations one by
one, within the same solution group.
Date/time the tissue processing ended.
Date/time the tissue processing is predicted to end. A predicted endtime is
specified when a program is created or edited.
Reset Solution Usage
Information
To clear solution usage information.
The following types of cleaning are performed:
Use xylene or alcohol to clean the retort of deposits of paraffin or solution.
Use warm water to flush the tubing of the instrument of precipitate build-ups.
(Warm Water Flush)
The entire volume of solution in the retort is pumped out/in.
Solution Configuration
Setting
To set the details of each solution group.
To start tissue processing immediately.
A function to start tissue processing according to the predicted endtime.
The instrument waits and starts tissue processing so that it will end at the predicted
endtime.
A management method that can be set for managing solutions. A desired value
between 1 and 99 days can be set.
To drain solution from a retort to a solution station.
To fill solution from a solution station to a retort.
A password used when permitted operations on the instrument are to be limited.
A station where tissue processing is performed.
A part that switches the path connecting a retort and each solution station.
To disable screen operations.
To enable screen operations by entering a password.