*1) Mode
- HP : Heat Pump, HR : Heat Recovery
*2) Nominal cooling capacities are based on;
- Indoor temperature : 27°C DB, 19°C WB
- Outdoor temperature : 35°C DB, 24°C WB, Equivalent piping length : 7.5m, Level differences : 0m
*3) Nominal heating capacities are based on;
- Indoor temperature : 20°C DB, 15°C WB
- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
1-1. Specifications
1) Technical specifications
(1) Basic model
RVXVHT080GE
3/ 380~415/ 50
HP
8
22.4
76,400
25.2
86,000
5.76
5.51
12.2
12.0
25
3.89
4.57
3MAF POE
Propeller/BLDC
170
8
78.5
High pressure switch
Crank Case Heater
Fuse for PCB
Over voltage protection
Current Transformer
Fan motor over heat/current protector
9.52
19.05
-
200
50 (40)
R410A
7.5
57
240
253
880 x 1,703 x 765
948 x 1,868 x 832
2.5
0.75~1.50
-5~43
-20~24
Installation Manual
Connector for condensate
ø/V/Hz
-
HP
kW
Btu/h
kW
Btu/h
kW
kW
A
A
A
-
-
-
-
EA
cc/Rev
kW
-
cc
-
W
m
3
/min
mmAq
Pa
-
-
-
-
-
-
ø, mm
ø, mm
ø, mm
m
m
-
kg
dB(A)
dB(A)
kg
kg
mm
mm
mm
2
mm
2
°C
°C
-
-
Type
Model
Performance
Power Supply
Mode*
1)
Basic
Horse Power
Capacity
Power
COP
Compressor
Fan
Safety
Devices
Piping
Connections
Refrigerant
Set Size
Cable
Operating
Temp. Range
Standard Accessories
Sound*
4)
Nominal input
Nominal running
current
Mechanical Type
Electronic Type
Liquid
Gas
Oil (Flare)
Installation Limitation
Type
Factory Charging
Sound Pressure
Sound Power
Net Weight
Shipping Weight
Net Dimensions (WxHxD)
Shipping Dimensions (WxHxD)
Main Power (Below 50m)
Communication
Cooling
Heating
Circuit Breaker (MCCB/ELB)
Cooling
Heating
Model
Type
Number
Piston Displacement
Output
Lubricant
Type/Control
Motor Output
Airflow Rate
External Static
Pressure
Cooling*
2)
Heating*
3)
Cooling
Heating
Cooling
Heating
Type
Charging
Max.
Max. Length
Max. Height
ZPJ61KCE-TFD
Digital scroll
1
58.1
4.93
1,685
ZPI61KCE-TFD
Fixed scroll
1
58.1
4.93
1,685
RVXVHT100GE
3/ 380~415/ 50
HP
10
28.0
95,500
31.5
107,500
7.78
7.16
13.9
13.0
30
3.60
4.40
3MAF POE
Propeller/BLDC
170
8
78.5
High pressure switch
Crank Case Heater
Fuse for PCB
Over voltage protection
Current Transformer
Fan motor over heat/current protector
9.52
22.23
-
200
50 (40)
R410A
7.5
58
240
253
880 x 1,703 x 765
948 x 1,868 x 832
2.5
0.75~1.50
-5~43
-20~24
Installation Manual
Connector for condensate
ZPJ61KCE-TFD
Digital scroll
1
58.1
4.93
1,685
ZPI61KCE-TFD
Fixed scroll
1
58.1
4.93
1,685
RVXVHT120GE
3/ 380~415/ 50
HP
12
33.6
114,600
37.8
129,000
10.40
9.40
21.0
19.2
40
3.23
4.02
3MAF POE
Propeller/BLDC
180
8
78.5
High pressure switch
Crank Case Heater
Fuse for PCB
Over voltage protection
Current Transformer
Fan motor over heat/current protector
12.70
25.40
-
200
50 (40)
R410A
7.5
60
240
253
880 x 1,703 x 765
948 x 1,868 x 832
4
0.75~1.50
-5~43
-20~24
Installation Manual
Connector for condensate
ZPJ83KCE-TFD
Digital scroll
1
77.2
8.02
1,685
ZPI83KCE-TFD
Fixed scroll
1
77.2
8.02
1,685
RVXVHT140GE
3/ 380~415/ 50
HP
14
39.2
133,800
44.1
150,500
11.00
10.40
24.2
23.0
40
3.56
4.24
3MAF POE
Propeller/BLDC
210
8
78.5
High pressure switch
Crank Case Heater
Fuse for PCB
Over voltage protection
Current Transformer
Fan motor over heat/current protector
12.70
25.40
-
200
50 (40)
R410A
11.0
60
320
337
1,200 x 1,703 x 765
1,268 x 1,868 x 832
4
0.75~1.50
-5~43
-20~24
Installation Manual
Connector for condensate
ZPJ72KCE-TFD
Digital scroll
1
67.1
5.81
1,685
ZPI61KCE-TFD
Fixed scroll
2
58.1
4.93
1,685
RVXVHT160GE
3/ 380~415/ 50
HP
16
44.8
152,900
50.4
172,000
14.80
15.00
28.6
29.2
50
3.03
3.36
3MAF POE
Propeller/BLDC
210
8
78.5
High pressure switch
Crank Case Heater
Fuse for PCB
Over voltage protection
Current Transformer
Fan motor over heat/current protector
12.70
28.58
-
200
50 (40)
R410A
11.0
60
320
337
1,200 x 1,703 x 765
1,268 x 1,868 x 832
6
0.75~1.50
-5~43
-20~24
Installation Manual
Connector for condensate
ZPJ72KCE-TFD
Digital scroll
1
67.1
5.81
1,685
ZPI72KCE-TFD
Fixed scroll
2
67.1
5.81
1,685
Outdoor Units
III-6
1
1
DVM PLUS III, DVM PLUS III HR
DVM PLUS III
3-1.DVM,HR3_Outdoor(002~037) 3/21/08 11:19 Page 6