Guide for docking connection error (Mechanical)
Check Cabinet status.
- Additional insertion is carried out by applying a load on the bracket-frame to prevent cabinet not inserted.
※ When applying the load, apply the load only to BRACKET-FRAME so that there is no damage to the LED module.
Check Docking connection status
Check the status after pressing Docking in the up-down direction. (Fig1. )
Remove the four screws for docking and press them again in the up-down direction.
After checking the status, fasten the four screws and fix the docking. (Fig2. )
If a connection error occurs again after fastening four screws,
remove two screws for the upper dock (bottom of the cabinet standard)
and press them in the up-down direction to check the connection status. (Fig3. )