LED R&D Lab(VD)
32
Check AC power supply
- Check the AC switch on the right side (in the top direction)
The switch disconnects the AC supply at the bottom and must be supplied from the following cabinet.
※ However, it is not necessary to connect the AC cable separately.
Check signal connection
Insert service key to Docking Connector.
Tack Switch Click.
OSD “ No Video ” is displayed when power is turned on.
If "No Video" is not output, recheck the AC power supply above is required.
The "No Video" is also displayed in the following cabinet connected to Docking.
Sequentially, “No Video“ is displayed in the cabinet in the following direction.
If the Cabinet “No Videobelow is not output, the connection terminal needs to be checked.
i) After AC power Off -> Disassembly LED module -> AC power On
ii) After assembly LED module, Check Connection green LED ,
“DOCK_CHECK_B”, “DOCK_CHECK_T
Guide for docking connection error (Circuit)
1
2
3
4
t
b
1. Product Information and Installation Precautions

Table of Contents

Related product manuals