LED R&D Lab(VD)
201
Appendix 2 - S-Box Installation and Connection
It is recommended to install it in a 19inch Server rack.
Install so that the vents are open and do not turn sideways or overturn.
Be careful as blocking the ventilation holes may cause the product to overheat.
When installing multiple S-Boxes, install them at least 1U (44.45mm) away from the top product.
When installing on a wall, the product must be 10mm or more apart from the wall in the vertical, left and right,
and in the case of a cable port, install it 50mm or more apart for cable connection.
Keep the residual heat inside the rack below 35°C.
Be careful not to let liquids, etc., enter the product's ventilation holes.
• Cautions when installing S-Box (SNOWJAU/SNOWAAE)
SNOWJAU
SNOWAAE