58 VERSA SATEL
ASD-150 – enter 2 digits:
1
st
digit – option to signal alarm from other ASD-150 detectors: 0 (disabled) or 1 (enabled).
2
nd
digit – option to send out alarm to other ASD-150 detectors: 0 (disabled) or 1
(enabled).
AVD-100 – for the magnetic contact, enter the digit 0 (bottom reed switch) or 1 (side reed
switch) to determine which of the two reed switches is to be active. For the vibration
detector, enter 2 digits:
1
st
digit – sensitivity: from 1 to 8 (1 – minimum; 8 – maximum).
2
nd
digit – number of pulses: from 0 to 7. For the value 0, pulses are not counted.
ASP-100 – enter 2 digits:
1
st
digit – type of acoustic signaling: from 1 to 4.
2
nd
digit – maximum duration of signaling: 1 (1 minute), 2 (3 minutes), 3 (6 minutes) or 4 (9
minutes).
ASP-105 – enter 2 digits:
1
st
digit – type of acoustic signaling: from 1 to 4.
2
nd
digit – maximum duration of acoustic signaling: 1 (1 minute), 2 (3 minutes), 3 (6
minutes) or 4 (9 minutes).
ASP-205 – for both positions taken on the list by the siren, enter 3 digits:
1
st
digit – maximum duration of signaling: 1 (1 minute), 2 (3 minutes), 3 (6 minutes) or 4
(9 minutes).
2
nd
digit – type of acoustic signaling: 0 (disabled), 1 (sound type 1), 2 (sound type 2) or 3
(sound type 3).
3
rd
digit – optical signaling: 0 (disabled) or 1 (enabled).
ASW-100 E / ASW-100 F – enter 0 (only remote control of the electric circuit); 1 (remote or
manual control of the electric circuit) or 2 (remote or manual control of the electric circuit,
but with option to manually block the remote control).
LCD keypad
You can configure the operating parameters of wireless device:
immediately after adding the device to the system (for the procedure of adding ABAX
wireless devices, refer to the INSTALLER MANUAL),
using the C
ONFIG.DEVICE function (SERVICE MODE 2. HARDWARE 1. KPDS & EXPS
3. W
IRELESS DEV. 2. CONFIG.DEVICE). Having started the function, use the and
keys to select the zone to which the wireless device is assigned and press .
The programming is performed using the “step by step” method (see: p. 6). Described below
are programming settings for the wireless devices for which additional configurable options
and parameters are available.
AGD-100 detector
1. Enter a number from the 0 to 50 range to define the rules of device presence control, and
then press .
2. Press any numeric key to define whether the detector is to be always active ( – no, –
yes), and then press .
3. Enter a digit from the 1 to 3 range to define sensitivity (1 – low, 2 – medium, 3 – high),
and then press
.